Search results for "Lung Compliance"

showing 6 items of 6 documents

Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.

1986

The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…

AdultMaleSpecific forcePhysiologyElectromyographyPublic Health Environmental and Occupational HealthSTRIDEGeneral MedicineAnatomyConcentricElasticityBiomechanical PhenomenaRunningPhysiology (medical)EccentricHumansOrthopedics and Sports MedicineForce platformFemaleGround reaction forceBiomechanics of sprint runningLung ComplianceBiomedical engineeringResultant forceMathematicsEuropean journal of applied physiology and occupational physiology
researchProduct

Impact of the Prone Position in an Animal Model of Unilateral Bacterial Pneumonia Undergoing Mechanical Ventilation

2013

Abstract Background: The prone position (PP) has proven beneficial in patients with severe lung injury subjected to mechanical ventilation (MV), especially in those with lobar involvement. We assessed the impact of PP on unilateral pneumonia in rabbits subjected to MV. Methods: After endobronchial challenge with Enterobacter aerogenes, adult rabbits were subjected to either “adverse” (peak inspiratory pressure = 30 cm H2O, zero end-expiratory pressure; n = 10) or “protective” (tidal volume = 8 ml/kg, 5 cm H2O positive end-expiratory pressure; n = 10) MV and then randomly kept supine or turned to the PP. Pneumonia was assessed 8 h later. Data are presented as median (interquartile range). Re…

Maleend-expiratory pressureSupine positionEndpoint Determinationmedicine.medical_treatmentrecruitment maneuverPeak inspiratory pressureLung injuryPulmonary compliancerabbit modelPositive-Pressure RespirationPneumonia BacterialProne PositionSupine PositionmedicineAnimalsratLungLung ComplianceTidal volumeInflammationMechanical ventilationrespiratory-distress-syndromecyclic stretchPulmonary Gas ExchangeTumor Necrosis Factor-alphabusiness.industryInterleukin-8Enterobacteriaceae InfectionsHemodynamicsEnterobacter aerogenesmedicine.diseaseRespiration ArtificialPneumoniaProne positiongas-exchangeAnesthesiology and Pain Medicineacute lung injuryAnesthesia[SDV.SPEE]Life Sciences [q-bio]/Santé publique et épidémiologieRabbitstidal volume ventilationbusinessair-space enlargementAnesthesiology
researchProduct

Helmet continuous positive airway pressure and prone positioning: A proposal for an early management of COVID-19 patients

2020

In late December 2019, clusters of patients with interstitial pneumonia of unknown cause were reported by some local health facilities in Wuhan (China). The Chinese Centre for Disease Control conducted an epidemiologic and etiologic investigation, leading to the identification of a novel coronavirus (SARS-CoV-2).1, 2 On March 11th, the World Health Organization (WHO) declared the novel coronavirus disease (COVID-19) a pandemic. In the area of Wuhan, COVID-19 mainly affected male patients (around 60%), with a median age of about 50 years; 40% of patients developed Acute Respiratory Distress Syndrome (ARDS) 5% requiring intensive care. The mortality rate was around 2%.3, 4 However, Grasselli …

Pulmonary and Respiratory Medicine2019-20 coronavirus outbreakmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)medicine.medical_treatmentSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Pneumonia ViralcoronavirusArticlePatient PositioningPositive-Pressure RespirationBetacoronavirusPandemicmedicineHumansContinuous positive airway pressurePositive-Pressure RespirationHypoxiaLung CompliancePandemicslcsh:RC705-779Respiratory Distress SyndromeContinuous Positive Airway PressurebiologySARS-CoV-2business.industryhelmetCOVID-19lcsh:Diseases of the respiratory systembiology.organism_classificationProne positionVasoconstrictionprone positionEmergency medicineHead Protective DevicesCoronavirus InfectionsRespiratory InsufficiencybusinessBetacoronavirusCPCP COVID-19 SARS-CoV-2
researchProduct

Mechanostructural adaptations preceding postpneumonectomy lung growth

2012

In many species, pneumonectomy results in compensatory growth in the remaining lung. Although the late mechanical consequences of murine pneumonectomy are known, little is known about the anatomic adaptations and respiratory mechanics during compensatory lung growth. To investigate the structural and mechanical changes during compensatory growth, mice were studied for 21 days after left pneumonectomy using microCT and respiratory system impedance (FlexiVent). Anatomic changes after left pneumonectomy included minimal mediastinal shift or chestwall remodeling, but significant displacement of the heart and cardiac lobe. Mean displacement of the cardiac lobe centroid was 5.2 ± 0.8 mm. Lung imp…

Pulmonary and Respiratory Medicinemedicine.medical_specialtymedicine.medical_treatmentHysteresivityClinical BiochemistryMediastinal ShiftRespiratory physiologyPulmonary complianceBiologyArticleMicePneumonectomyInternal medicineRespirationmedicineAnimalsRegenerationPostoperative PeriodRespiratory systemPneumonectomyThoracic WallLungLung ComplianceMolecular BiologyLungRespirationElectric ConductivityOrgan SizeX-Ray MicrotomographyAnatomyAdaptation PhysiologicalElasticityMice Inbred C57BLDisease Models Animalmedicine.anatomical_structureCardiologyLung Volume MeasurementsExperimental Lung Research
researchProduct

Dynamic determination of oxygenation and lung compliance in murine pneumonectomy.

2011

Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, the authors investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55% to 82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10 mL/kg. Sustained inflation pressu…

Pulmonary and Respiratory Medicinemedicine.medical_treatmentClinical BiochemistryPulmonary complianceArticlePositive-Pressure RespirationPneumonectomyMiceTidal VolumeMedicineAnimalsLung volumesAnesthesiaPneumonectomyMolecular BiologyLungLung ComplianceTidal volumeOxygen saturation (medicine)Mechanical ventilationLungbusiness.industryTotal Lung CapacityOxygenationrespiratory systemRespiration ArtificialMice Inbred C57BLOxygenmedicine.anatomical_structureAnesthesiabusinessLung Volume MeasurementsExperimental lung research
researchProduct

Respiratory mechanics measured by forced oscillations during mechanical ventilation through a tracheal tube

2011

The forced oscillation technique (FOT) allows the measurement of respiratory mechanics in the intensive care setting. The aim of this study was to compare the FOT with a reference method during mechanical ventilation through a tracheal tube. The respiratory impedance spectra were measured by FOT in nine anaesthetized pigs, and resistance and compliance were estimated on the basis of a linear resistance-compliance inertance model. In comparison, resistance and compliance were quantified by the multiple linear regression analysis (LSF) of conventional ventilator waveforms to the equation of motion. The resistance of the sample was found to range from 6 to 21 cmH(2)O s l(-1) and the compliance…

Time FactorsSwinePhysiologyCoefficient of variationmedicine.medical_treatmentBiomedical EngineeringBiophysicsRespiratory physiologyPulmonary complianceForced Oscillation TechniquePhysiology (medical)Intensive careStatisticsmedicineAnimalsLung ComplianceMathematicsMechanical ventilationbusiness.industryReproducibility of ResultsRepeatabilityReference Standardsrespiratory systemRespiration ArtificialInertanceTracheaRespiratory MechanicsNuclear medicinebusinessPhysiological Measurement
researchProduct